Brand | Beijing Zorpia | American CBS Series2100 | Thermo Scientific CryoMed | Australian Cryologic CL Series (Mini) | France Nicool FREEZAL | British Kryo | Austria SY-LAB |
temperature control | 40 °C ~ -180 °C | 50 °C ~ -180 °C | 50 °C ~ -180 °C | 40 °C ~ -120 °C, 20 °C ~ -43 °C | 40 °C ~ -180 °C | 40 °C ~ -180 °C | 40 °C ~ -180 °C |
Cooling rate | 0.1 to 50 °C / min | 0.01 to 99 °C / min | 0.1 to 50 °C / min | Cooling rate up to 8 °C / min | 0.1 to 25 °C / min | 0.01 to 50 °C / min | 0.01 to 60 °C / min |
Heating rate | 0.1 to 30 °C / min | Fastest 20 °C / min | 0.1 to 10 °C / min | Maximum heating rate: ~ 15 °C / min (at -43 °C) | 0.01 to 10 °C / min | 0.01 to 15 °C / min | |
deviation | ± 0.5 °C | Deviation limit: Time: 0.01 ~ 99.9 °C / min Temperature: 1-180 °C | Less than 2 °C | Non-limit speed cooling can reach 120 °C / min | |||
structure | Stainless steel construction, silent, polyester thermoformed liner reduces box deformation, silicone heat ring around the door, ensuring complete sealing | Outside is glazed steel | Stainless steel construction, silent, polyester thermoformed liner reduces box deformation, silicone heat ring around the door, ensuring complete sealing | Mute | Stainless steel liner with open top transparent cover for user observation | ||
The electromagnetic valve | Two solenoid valves are used alternately to extend the life of the solenoid valve | Two solenoid valves are used alternately to extend the life of the solenoid valve | |||||
Door lock | Have | Have | Have | ||||
Return air duct design, increase air convection and improve temperature uniformity | Air handler to increase air convection and improve temperature uniformity | ||||||
Built-in fan design | Built-in fan (with protective net) to evenly disperse the injected liquid nitrogen to ensure uniformity of sample temperature in the freezer | Built-in fan can evenly disperse the injected liquid nitrogen to ensure the uniformity of sample temperature in the freezer. External door opening will automatically stop liquid nitrogen injection and fan rotation. | Built-in fan (with protective net) can evenly disperse the injected liquid nitrogen to ensure the uniformity of sample temperature in the freezer. External door opening will automatically stop liquid nitrogen injection and fan rotation. | During the work process, the cover is closed to stop all operations, and the liquid nitrogen system has a safety relief valve. | |||
control method | Microcomputer computer control | Laptop, Window operating system | Microcomputer or computer control | Microcomputer computer control | Windows XP operating system, 3 USB ports and RJ45 network interface | Micro-processing control, optional Delta TPC software to connect to the computer | The computer transmits data via RS232 cable and RISC micro-controller connection, operating system MS Windows TM |
display screen | 19 liquid crystal display | 14 -inch color screen | 4 × 20 liquid crystal display | Digital liquid crystal display | Touch the big screen | Four-line LCD display | |
Default program | Can be preset a number of programs (depending on the size of the computer hard disk, basically unlimited) | 6 programmed programs can be selected, multi-level password protected entry program; program execution ends, sound and light prompts Each running program contains 30 storage parameters, of which 27 are searchable parameters and 3 are auxiliary parameters. Choose a password protection level | Preset 6 kinds of freezing programs, users can program independently according to the experiment, and can store up to 10 sets of user programs ( 16 steps in each group). | 16 , 8 , none, all temperature control can be pre-programmed or temporarily set (when connected to a computer) | MRV controller, 10 32- step programs, flexible editing, storage and recall, users can use password protection program | ||
Temperature control | Double temperature control probe detects the temperature inside the box and the temperature of the sample respectively. The measured temperature is closer to the actual temperature. The display can display the temperature inside the box and the temperature of the sample. | Temperature control set point, can choose box temperature or sample temperature, can scan detection display all the way, and has cooling waiting function, dual temperature control probe, respectively detect the temperature inside the box and sample temperature | Double temperature control probe detects the temperature inside the box and the temperature of the sample respectively. The measured temperature is closer to the actual temperature. The display can display the temperature inside the box and the temperature of the sample. | Temperature can be maintained at any point within the controlled temperature range | Dual temperature control probes, respectively detect the temperature inside the box and the temperature of the sample, and have convenient ice water temperature correction function. | ||
Program setting | Unlimited program settings | Unlimited program settings | Unlimited programming if controlled by computer software | Can store unlimited programs | |||
Can be equipped with a printer, color record registration sample, cabinet and program temperature | Can be equipped with a printer, color record registration sample, cabinet and program temperature | Built-in thermal printer or external printer | Easy temperature curve printing via USB interface | Built-in thermal printer to record samples, freezer and program temperature changes | |||
display | The computer displays the temperature inside the box, the temperature of the sample, and the working status in real time. | Continuous digits and graphs showing time and temperature | LCD real-time display box temperature, sample temperature, working status, prompt error message | Display freezing program | The graphic shows the connected temperature probe temperature curve, detailed parameter settings, easy to operate and monitor | ||
Storage location | Data is saved on the computer | Store program and frozen data to hardware or diskette | Save the program to your computer or storage device | Save the program to your computer | Data is saved on the computer | ||
Power failure protection | no | Have | Power-off restart: Since the structure of the control box is adopted, once the program is running, the computer only plays the display function, and the call control box can continue to work after the power is cut off. | ||||
Probe | Platinum resistance temperature sensor for continuous and accurate monitoring of sample and freezer temperature | Safety features such as thermocouple temperature probe error alarm | Platinum resistance temperature sensor, when the temperature of the freezing tank exceeds or falls below the specified temperature of 1.5 °C, the system will automatically emit an audible and visual alarm signal. | Platinum resistance temperature sensor for continuous and accurate monitoring of sample and freezer temperature | |||
size | Internal dimensions: 10 liters | External dimensions: 635 × 609 × 533mm Internal dimensions: 241 × 342 × 342mm (28 liters ) | 17 liters, 34 liters, 48 liters | 90 × 195 × 225mm     118 × 192 × 220mm     90 × 155 × 175mm | Freezer cavity: 210 × 210 × 320 External dimensions: 534 × 536 × 467 | ||
Temperature recording device | Software can record detailed parameters of temperature changes, graphics | Optional plus warning lights to complete each run, temperature turn, freeze operation record | |||||
save | Keep all data and procedures for quality control testing | Search for previous frozen records | Call to save 12 set programs, the saved data can be exported in various formats | Exclusive automatic data recovery system | Keep all data and procedures for quality control testing | ||
Planting ice | can | Optional manual, automatic | Optional automatic | Optional automatic |
21" Sanitary Sleeve For Embryo Transfer
21 Inches Sanitary Sleeve,Disposable Sanitary Chemise,Embryo Transfer Cover,Et Sheath Cover
Jinan Mucho Commercial Inc. , https://www.muchovet.com