What to do when the pump valve packing leaks

Leakage at the packing (outer leakage of the valve, the proportion of the packing is large)

the reason:

1. The filler is not selected correctly, it is not resistant to the corrosion of the medium, and is not resistant to the use of high pressure or vacuum, high temperature or low temperature of the valve;

2. The filler is not installed correctly, and there are defects such as small generation, poor spiral coiled joints, tightness and looseness;

3. The filler has exceeded the service life, has aged, and lost its elasticity. The valve stem has low precision and has defects such as bending, corrosion and wear. The number of packing rings is insufficient, and the gland is not pressed;

6. Damage to the gland, bolts, and other components so that the gland cannot be pressed;

7. Improper operation, excessive force, etc.;

8. The gland is skewed, and the gap between the gland and the valve stem is too small or too large, causing the stem to wear and the packing to be damaged.

Maintenance method:

1. The material and type of the filler shall be selected according to the working conditions;

2. According to the relevant provisions of the correct installation of packing, the packing should be placed in a ring-by-turn compression, the joint should be 30 ° C or 45 ° C;

3. Fillers that are too long, aging, and damaged should be replaced in time;

4. After the valve stem is bent and worn, it should be straightened and repaired. If the damage is serious, it should be replaced in time;

5. The packing shall be installed according to the specified number of turns, the gland shall be tightly and symmetrically tightened, and the press sleeve shall have a pre-tightening clearance of more than 5 mm;

6. Damaged glands, bolts and other components should be repaired or replaced in time;

7. The operating procedures shall be observed, and the normal force shall be operated at a constant speed in addition to the impact hand wheel;

8. The gland bolt should be tightened evenly symmetrically, and the gap between the gland and the valve stem should be too small, and the gap should be appropriately increased;

The gap between the gland and the stem is too large and should be replaced.

Autoclave Auxiliary Equipment

When using a steam autoclave, a lot of auxiliary equipment is needed to support the daily use of the sterilizer: you will use a water distilling machine to produce distilled water to avoid corrosion of the sterilizer pipeline due to poor water quality; you will You will need to seal the bag to hold the surgical instruments, and then use the Sealing Machine to make it into a sealed environment; you need dental handpiece maintenance equipment to clean and fill the dental handpiece with lubricating oil; you also need an Ultrasonic Cleaner to put the surgical instruments in Before the sterilizer, of course you need to clean it first. The ultrasonic cleaner can remove the dirt from the corners, which is safe and convenient. Of course, if you have the ultimate pursuit of safety and health, you will also use our sterilization effect test box. We, ESCO MEDCO, are a medical product company specializing in sterilizers and auxiliary equipment. It has a history of more than ten years. Its export volume ranks among the top three in the country throughout the year. The annual sales volume of sterilizer products exceeds 12,000. Sold in more than one hundred countries and regions all over the world.